A field is a kind of laboratory rather than a category of instrument. You choose what you do, and the instrument catalogue, the saved check plans, the standards cited and the document produced all follow from it. 13 fields and 57 instrument types, and a laboratory that does two of them never sees the other eleven.
Calibration — what an instrument reads against a reference
These produce a calibration certificate: traceability to national standards, a stated uncertainty, the declared decision rule, and a grade where the method defines one.
Force and post-tensioning
Hydraulic jacks, jacking systems and load cells for post-tensioning, civil and structural work.
Standards
AS 2193-2005 · ISO 376
Instruments
Pre-Stress Jack, Jacking System, Sag Pull Gauge, Load Cell, Force Gauge, Crane Scale
Interval
Six months for jacks in service, twelve for load cells. A jack on a site is worked hard and drifts; a load cell in a laboratory does not.
Electrical test instruments
Multimeters, clamp meters, insulation, RCD, appliance and multifunction testers — the instruments an electrical contractor tests with.
Twelve months for workshop use, six where an instrument is in daily production.
Gas and environment
Gas detectors, anemometers, sound level meters, moisture meters, flow meters.
Standards
AS/NZS 60079 · AS/NZS 1269 · Manufacturer’s published specification
Instruments
Gas Detector, Anemometer, Sound Level Meter, Moisture Meter, Flow Meter
Interval
Six months for gas detectors, twelve for the rest. A gas detector is life-safety equipment and a bump test between calibrations is the customer’s job, not the laboratory’s.
Medical devices
Blood-pressure monitors, scales, oximeters, glucometers, dopplers and ABI machines in medical centres and practices.
Standards
AS/NZS 3551 · Manufacturer’s published specification
Instruments
Blood Pressure Monitor, Medical Scale, Thermo Scan, Oximeter, Glucometer, Doppler, ABI Machine, Body Composition Analyser
Interval
Twelve months, and what a practice’s own accreditation asks for where that is shorter.
Site and workshop equipment
Laser levels, welding machines, metal detectors, tint meters.
Standards
Manufacturer’s published specification
Instruments
Laser Level, Welding Machine, Metal Detector, Tint Meter
Interval
Twelve months. These are mixed equipment with no common standard behind them, so the manufacturer’s recommendation decides it more often than convention does.
4 fields · in-service inspection
Inspection — whether an item met a standard’s criteria
These produce an inspection report. It states the criteria, the readings and the outcome, and asserts nothing about the item’s measurement accuracy, because nothing was measured about it. No grade, and never an accreditation mark.
Test and tag — in-service inspection
Testing and tagging appliances, leads and RCDs in service. High volume: hundreds of items a day, most of them passing.
Standards
AS/NZS 3760 · AS/NZS 3012 · AS/NZS 3017
Items
Electrical Safety Test and Tag
Interval
Three months on construction and demolition sites (AS/NZS 3012), six to twelve in an office or a workshop. The same appliance, a different environment — so the interval is the customer’s circumstance rather than a property of the item, and this is the one field where getting that wrong is common.
Electrical safety equipment
Insulating gloves, mats and blankets — proof-tested rather than calibrated.
Standards
AS 2225 · IEC 60903 · AS/NZS 2978
Items
Insulating Glove, Insulating Mat
Interval
Six months for gloves in service, twelve for mats. Shorter than most fields because the consequence of a failure is electrocution rather than a wrong number.
Lifting and height safety
Slings, chains, harnesses and lifting equipment inspected for continued service.
Standards
AS 2550 · AS/NZS 1891
Items
Lifting Equipment
Interval
Six or twelve months by equipment class, and after any shock load.
Medical equipment safety testing
Electrical safety and performance verification of medical equipment — beds, autoclaves, nebulisers, examination equipment — under AS/NZS 3551.
Standards
AS/NZS 3551 · IEC 60601
Items
Medical Bed, Autoclave, Nebuliser, Otoscope / Examination Scope
Interval
Twelve months, or as the equipment’s own risk classification requires.
Why the difference is enforced rather than documented. The discriminator is the item, not the shape of the check. A 500 V insulation tester must deliver at least its rated voltage at rated current under AS/NZS 3763 — a one-sided limit inside a genuine calibration. Calibrating an RCD tester against a reference is calibration; testing an RCD in a switchboard is inspection. Same standard, same measurement, different document, because the item is a different kind of thing.
AS/NZS 3760 · AS/NZS 3012 · AS/NZS 3017
Electrical test and tag, in depth
The largest of the thirteen fields by volume, and the least like the others. Hundreds of items a day rather than one instrument in an afternoon, almost all of them passing, and an inspection report at the end rather than a certificate.
The batch grid, not the bench sheet
Hundreds of appliances, leads and RCDs a day, entered across a grid rather than down a form. The bench sheet is right for one jack in an afternoon and wrong for a pallet of kettles, and the two sit beside each other so a technician chooses by what is on the trolley.
One-sided limits, properly modelled
AS/NZS 3760 bounds earth resistance in one direction only — ≤ 1 Ω, with nothing to say about how much lower is better. A tolerance band with a lower limit invented to fill the field is a fabricated criterion on a safety document, so the engine carries genuine one-sided limits and go/no-go checks with no numeric reading at all.
An inspection report, and never a certificate
An appliance is not calibrated, and heading its document “Calibration Certificate” tells a reader something that cannot be true of a kettle. The discriminator is the item rather than the shape of the check, it is stored on the document at issue, and the accreditation mark is refused rather than explained in a footnote.
Test tags that say next test due
The tag on the appliance reads the date the person holding it needs, printed as ZPL straight to the printer. It carries a QR code like everything else, so a site supervisor can check the item without an account, an app or a phone call to your office.
Three months on a site, twelve in an office
The interval is the customer’s environment rather than a property of the appliance, and the same kettle is due at different times in different places. Intervals are set per instrument type and overridden per item, and the recall ladder follows whatever was actually recorded.
Recorded where there is no signal
A switchboard room, a basement, a construction site. Readings are captured on the device and sync when it reconnects — and the engine deliberately does not run offline, because everything that makes the document defensible depends on checks that cannot run on a handset.
57 instrument types
The catalogue
Sorted by physical quantity rather than by field, because the two are different questions: “Electrical” holds a spectrum analyser and an appliance tester, and no business does both. Each type carries a default interval and a pinned calculation template — and a laboratory may add its own, because a catalogue is a starting point and not a ceiling.
Force6 types
Anything measuring or applying a load — the post-tensioning and structural end of the trade.
Pre-Stress Jack6 mo
Jacking System6 mo
Sag Pull Gauge6 mo
Load Cell12 mo
Force Gauge12 mo
Crane Scale12 mo
Electrical18 types
What an electrical contractor tests with, what tests them, and the safety equipment around both.
NST Tester12 mo
Clamp Meter12 mo
Multimeter12 mo
Appliance Tester12 mo
RCD Tester12 mo
Insulation Tester12 mo
Multifunction Tester12 mo
Cable Locator12 mo
Electrical Safety Test and Tag3 mo
Insulating Glove6 mo
Insulating Mat12 mo
Proving Unit12 mo
Safety Analyser12 mo
EMF / Field Meter12 mo
Spectrum Analyser12 mo
Network Analyser12 mo
Optical Power Meter12 mo
Optical Source12 mo
Physical20 types
The broadest group: torque, pressure, temperature, dimension, gas, sound, flow, and site gear.
Torque Wrench12 mo
Torque Tester12 mo
Pressure Gauge12 mo
Thermometer12 mo
Welding Gauge12 mo
Welding Machine12 mo
Laser Level12 mo
Gas Detector6 mo
Anemometer12 mo
Caliper12 mo
Micrometer12 mo
Length Standard12 mo
Metal Detector12 mo
Sound Level Meter12 mo
Tint Meter12 mo
Moisture Meter12 mo
Coating Thickness Gauge12 mo
Thermal Imager12 mo
Flow Meter12 mo
Lifting Equipment12 mo
Medical13 types
Devices in practices, clinics and medical centres, and the safety testing around them.
Blood Pressure Monitor12 mo
Medical Scale12 mo
Medical Fridge12 mo
Thermo Scan12 mo
Oximeter12 mo
Glucometer12 mo
Doppler12 mo
ABI Machine12 mo
Medical Bed12 mo
Otoscope / Examination Scope12 mo
Nebuliser12 mo
Autoclave12 mo
Body Composition Analyser12 mo
The interval is advice, not a rule. It is the laboratory’s decision and in some fields the customer’s environment decides it — test and tag is the clearest case, at three months on a construction site and twelve in an office, for the same appliance either way.
Not seeing your field?
Nothing stops a laboratory booking in an instrument outside the fields it chose, and a new instrument type takes minutes to add. Three disciplines are sold separately because each carries its own standard and its own assessment rather than more of the same work: medical (AS/NZS 3551), hazardous areas (AS/NZS 60079) and legal metrology.